Teacher Notes

A. Prior to the lesson:

1. Arrange students into groups. Each group needs at least ONE person who has a mobile device.

2. If their phone camera doesn't automatically detect and decode QR codes, ask students to

3. Print out the QR codes.

4. Cut them out and place them around your class / school.


B. The lesson:

1. Give each group a clipboard and a piece of paper so they can write down the decoded questions and their answers to them.

2. Explain to the students that the codes are hidden around the school. Each team will get ONE point for each question they correctly decode and copy down onto their sheet, and a further TWO points if they can then provide the correct answer and write this down underneath the question.

3. Away they go! The winner is the first team to return with the most correct answers in the time available. This could be within a lesson, or during a lunchbreak, or even over several days!


C. TIPS / OTHER IDEAS

4. A detailed case study in how to set up a successful QR Scavenger Hunt using this tool can be found here.


Questions / Answers (teacher reference)

Question

Answer

1. What is the optimal water pressure for an Un-Vented Hot Water Installation?3 Bar
2. List the three temperature safety devices fitted to UVHWSC?Cylinder stat, Thermal Cut Off and T&P Relief Valve.
3. What's the difference between a Unit and a Package? Unit comes with all the components factory fitted. The Package only has the safety devices fitted, all the other components require fitting.
4. What is the maximum pipe length of D1?600mm.
5. Explain the process required to work out the pipe diameter for D2.Distance from termination plus fittings.

 



Un-Vented Hot Water: QR Challenge

https://www.classtools.net/QR/decode.php?text=What_is_the_optimal_water_pressure_for_an_Un-Vented_Hot_Water_Installation?

Question 1 (of 5)

 



Un-Vented Hot Water: QR Challenge

https://www.classtools.net/QR/decode.php?text=List_the_three_temperature_safety_devices_fitted_to_UVHWSC?

Question 2 (of 5)

 



Un-Vented Hot Water: QR Challenge

https://www.classtools.net/QR/decode.php?text=What's_the_difference_between_a_Unit_and_a_Package?

Question 3 (of 5)

 



Un-Vented Hot Water: QR Challenge

https://www.classtools.net/QR/decode.php?text=What_is_the_maximum_pipe_length_of_D1?

Question 4 (of 5)

 



Un-Vented Hot Water: QR Challenge

https://www.classtools.net/QR/decode.php?text=Explain_the_process_required_to_work_out_the_pipe_diameter_for_D2.

Question 5 (of 5)